[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fHXnJHc7RYFVy-gL--r34jJfFEH9Zz9gxJt6FBq3_qYQ":3,"g5a-ex:siemens\u002Fsimatic_s7-410_firmware@*":66,"g5a-family:siemens\u002Fsimatic_s7-410_firmware":68},{"success":4,"data":5},true,{"product":6,"versions":20,"topVulnerabilitiesByEpss":23,"kevVulnerabilities":43,"seoMetadata":44,"meta":63},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":19},"siemens","simatic_s7-410_firmware",2,3,0,"2018-12-13",[14,17],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"8.1",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"8.2.1","Simatic S7-410 Firmware by Siemens is a technology product with 2 tracked versions and 3 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[21,22],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},[24,31,36],{"cveId":25,"description":26,"publishedDate":12,"cvssScore":27,"cvssVersion":28,"severity":29,"isKev":16,"epssScore":30},"CVE-2018-16556","A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003C V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.9), SIMATIC S7-400 PN\u002FDP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003C V8.2.1), SIPLUS S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Specially crafted packets sent to port 102\u002Ftcp via Ethernet interface, via\r\nPROFIBUS, or via Multi Point Interfaces (MPI) could cause the affected\r\ndevices to go into defect mode. Manual reboot is required to resume normal\r\noperation.\r\n\r\nSuccessful exploitation requires an attacker to be able to send specially\r\ncrafted packets to port 102\u002Ftcp via Ethernet interface, via PROFIBUS or Multi\r\nPoint Interfaces (MPI). No user interaction and no user privileges are\r\nrequired to exploit the security vulnerability. The vulnerability could allow\r\ncausing a denial of service condition of the core functionality of the CPU,\r\ncompromising the availability of the system.",7.5,"v3.1","High",0.01545,{"cveId":32,"description":33,"publishedDate":12,"cvssScore":34,"cvssVersion":28,"severity":29,"isKev":16,"epssScore":35},"CVE-2018-16557","A vulnerability has been identified in  SIMATIC S7-400 CPU 412-1 DP V7 (All versions),  SIMATIC S7-400 CPU 412-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-2 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 DP V7 (All versions),  SIMATIC S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 DP V7 (All versions),  SIMATIC S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416F-2 DP V7 (All versions),  SIMATIC S7-400 CPU 416F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003C V7.0.3), SIMATIC S7-400 H V4.5 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.9), SIMATIC S7-400 PN\u002FDP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003C V8.2.1), SIPLUS S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Sending of specially crafted packets to port 102\u002Ftcp via Ethernet interface\r\nvia PROFIBUS or Multi Point Interfaces (MPI) could cause a denial of service\r\ncondition on affected devices. Flashing with a firmware image may be required\r\nto recover the CPU.\r\n\r\nSuccessful exploitation requires an attacker to have network access to port\r\n102\u002Ftcp via Ethernet interface or to be able to send messages via PROFIBUS or\r\nMulti Point Interfaces (MPI) to the device. No user interaction is required.\r\nIf no access protection is configured, no privileges are required to exploit\r\nthe security vulnerability. The vulnerability could allow causing a\r\ndenial of service condition of the core functionality of the CPU,\r\ncompromising the availability of the system.",8.2,0.00821,{"cveId":37,"description":38,"publishedDate":39,"cvssScore":40,"cvssVersion":28,"severity":41,"isKev":16,"epssScore":42},"CVE-2018-4843","A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416F-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 Advanced (All versions \u003C V3.3), SIMATIC ET 200pro IM154-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200pro IM154-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200pro IM154-8FX PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200S IM151-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200S IM151-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V1.7.0), SIMATIC S7-1500 Software Controller (All versions \u003C V1.7.0), SIMATIC S7-300 CPU 314C-2 PN\u002FDP (All versions \u003C V3.3.16), SIMATIC S7-300 CPU 315-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 315F-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 315T-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317F-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317T-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 319-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 319F-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003C V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.9), SIMATIC S7-400 PN\u002FDP V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003C V8.1), SIMATIC WinAC RTX 2010 (All versions \u003C V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions \u003C V2010 SP3), SINUMERIK 828D (All versions \u003C V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIPLUS ET 200S IM151-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIPLUS NET CP 443-1 (All versions \u003C V3.3), SIPLUS NET CP 443-1 Advanced (All versions \u003C V3.3), SIPLUS S7-300 CPU 314C-2 PN\u002FDP (All versions \u003C V3.3.16), SIPLUS S7-300 CPU 315-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 315F-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 317-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 317F-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system.\r\n\r\nThe security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system.","2018-03-20",6.5,"Medium",0.00543,[],{"title":45,"metaDescription":46,"keywords":47,"structuredData":48},"Simatic S7-410 Firmware by Siemens - Security Vulnerabilities & Analysis | EdgeProtect","Comprehensive security analysis for Simatic S7-410 Firmware by Siemens covering 2 versions with 3 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic S7-410 Firmware vulnerabilities, Simatic S7-410 Firmware security, Simatic S7-410 Firmware CVE, Siemens Simatic S7-410 Firmware, Simatic S7-410 Firmware threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":49,"@type":50,"name":51,"description":46,"url":52,"manufacturer":53,"applicationCategory":57,"softwareVersion":58,"mainEntity":59},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic S7-410 Firmware","https:\u002F\u002Fedgeprotect.io\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_s7-410_firmware",{"@type":54,"name":55,"url":56},"Organization","Siemens","https:\u002F\u002Fedgeprotect.io\u002Fvendors\u002Fsiemens","Security Software","2 versions tracked",{"@type":60,"name":61,"description":62,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Simatic S7-410 Firmware Security Vulnerabilities","Security vulnerabilities affecting Simatic S7-410 Firmware by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":64,"apiVersion":65},"2026-11-26T05:41:18.323Z","3.0",{"rows":67,"total":11,"capped":16,"failed":11},[],[]]