[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fedOD0x3lMEyGI_TOm9-ScrUIW35hCpAPAEAb7cVGLi4":3,"g5a-risk:CVE-2025-45492":126},{"success":4,"data":5,"meta":123},true,{"cveId":6,"title":7,"description":8,"shortDescription":8,"publishedDate":9,"lastModified":10,"cvssScore":11,"cvssVector":12,"cvssMetrics":13,"epssScore":40,"epssPercentile":26,"epssTimeSeries":41,"severity":43,"affectedProducts":44,"affectedProductsCount":55,"references":56,"referencesCount":55,"weaknesses":65,"weaknessesCount":74,"isActivelyExploited":54,"cisaInfo":26,"otxData":26,"relatedBlogPosts":75,"seoMetadata":76,"configurations":101,"relatedVendorCves":114,"notableEvents":115},"CVE-2025-45492","What is CVE-2025-45492?","Netgear EX8000 V1.0.0.126 is vulnerable to Command Injection via the Iface parameter in the action_wireless function.","2025-05-06T16:15:31.363","2026-06-17T09:25:33.44",9.8,"CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:H\u002FI:H\u002FA:H",{"CVSSMetricV31":14,"CVSSMetricV30":37,"CVSSMetricV2":38,"CVSSMetricV40":39},[15,29],{"Source":16,"Type":17,"CVSSData":18,"ExploitabilityScore":27,"ImpactScore":28},"nvd@nist.gov","Primary",{"Version":19,"VectorString":12,"AttackVector":20,"AttackComplexity":21,"PrivilegesRequired":22,"UserInteraction":22,"Scope":23,"ConfidentialityImpact":24,"IntegrityImpact":24,"AvailabilityImpact":24,"BaseScore":11,"BaseSeverity":25,"ExploitCodeMaturity":26,"RemediationLevel":26,"ReportConfidence":26,"TemporalScore":26,"TemporalSeverity":26,"ConfidentialityRequirement":26,"IntegrityRequirement":26,"AvailabilityRequirement":26,"ModifiedAttackVector":26,"ModifiedAttackComplexity":26,"ModifiedPrivilegesRequired":26,"ModifiedUserInteraction":26,"ModifiedScope":26,"ModifiedConfidentialityImpact":26,"ModifiedIntegrityImpact":26,"ModifiedAvailabilityImpact":26,"EnvironmentalScore":26,"EnvironmentalSeverity":26},"3.1","NETWORK","LOW","NONE","UNCHANGED","HIGH","CRITICAL",null,3.9,5.9,{"Source":30,"Type":31,"CVSSData":32,"ExploitabilityScore":27,"ImpactScore":36},"134c704f-9b21-4f2e-91b3-4a467353bcc0","Secondary",{"Version":19,"VectorString":33,"AttackVector":20,"AttackComplexity":21,"PrivilegesRequired":22,"UserInteraction":22,"Scope":23,"ConfidentialityImpact":21,"IntegrityImpact":21,"AvailabilityImpact":22,"BaseScore":34,"BaseSeverity":35,"ExploitCodeMaturity":26,"RemediationLevel":26,"ReportConfidence":26,"TemporalScore":26,"TemporalSeverity":26,"ConfidentialityRequirement":26,"IntegrityRequirement":26,"AvailabilityRequirement":26,"ModifiedAttackVector":26,"ModifiedAttackComplexity":26,"ModifiedPrivilegesRequired":26,"ModifiedUserInteraction":26,"ModifiedScope":26,"ModifiedConfidentialityImpact":26,"ModifiedIntegrityImpact":26,"ModifiedAvailabilityImpact":26,"EnvironmentalScore":26,"EnvironmentalSeverity":26},"CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:L\u002FI:L\u002FA:N",6.5,"MEDIUM",2.5,[],[],[],0.02206,[42,42,42,42,42,40,40],0.01345,"Critical",[45,50],{"vendor":46,"product":47,"version":48,"criteria":49,"vulnerable":4},"netgear","ex8000_firmware","1.0.0.126","cpe:2.3:o:netgear:ex8000_firmware:1.0.0.126:*:*:*:*:*:*:*",{"vendor":46,"product":51,"version":52,"criteria":53,"vulnerable":54},"ex8000","-","cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*",false,2,[57,62],{"url":58,"source":59,"tags":60},"https:\u002F\u002Fgithub.com\u002FJZP018\u002Fvuln03\u002Fblob\u002Fmain\u002Fnetgear\u002FEX8000\u002Fcve-netgear_EX8000_CI_action_wireless.pdf","GitHub",[61],"Exploit",{"url":63,"source":59,"tags":64},"https:\u002F\u002Fgithub.com\u002FJZP018\u002Fvuln03\u002Fblob\u002Fmain\u002Fnetgear\u002FEX8000\u002Fnetgear_EX8000_CI_action_wireless.mp4",[61],[66],{"id":67,"name":68,"description":69,"extendedDescription":70,"status":71,"abstraction":72,"structure":73},"CWE-77","Improper Neutralization of Special Elements used in a Command ('Command Injection')","The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.","Many protocols and products have their own custom command language. While OS or shell command strings are frequently discovered and targeted, developers may not realize that these other command languages might also be vulnerable to attacks.","Draft","Class","Simple",1,[],{"title":77,"metaDescription":78,"keywords":79,"canonicalUrl":80,"structuredData":81},"What is CVE-2025-45492? Vulnerability Analysis | Security Advisory | EdgeProtect","Comprehensive analysis of CVE-2025-45492, a critical severity cyber security vulnerability from 2025. Netgear EX8000 V1.0.0.126 is vulnerable to Command Inje...","CVE-2025-45492, CVE-2025-45492 vulnerability, CVE-2025-45492 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2025, CVSS score, exploit, patch, remediation, netgear security, ex8000_firmware vulnerability, ex8000 vulnerability","\u002Fwhat-is\u002Fcve-2025-45492",{"@context":82,"@type":83,"headline":77,"description":78,"datePublished":9,"dateModified":10,"author":84,"publisher":88,"about":92,"mainEntityOfPage":96,"articleSection":99,"keywords":100},"https:\u002F\u002Fschema.org","TechArticle",{"@type":85,"name":86,"url":87},"Organization","EdgeProtect","https:\u002F\u002Fedgeprotect.io",{"@type":85,"name":86,"url":87,"logo":89},{"@type":90,"url":91},"ImageObject","https:\u002F\u002Fedgeprotect.io\u002Fimg\u002Flogos\u002Fedgeprotect-logo-512.png",{"@type":93,"name":6,"description":94,"additionalType":95},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":97,"@id":98},"WebPage","https:\u002F\u002Fedgeprotect.io\u002Fwhat-is\u002Fcve-2025-45492","Cybersecurity","CVE-2025-45492, CVE-2025-45492 vulnerability, CVE-2025-45492 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[102],{"Operator":103,"Negate":26,"Nodes":104},"AND",[105,110],{"Operator":106,"Negate":54,"CPEMatch":107},"OR",[108],{"Vulnerable":4,"Criteria":49,"MatchCriteriaID":109,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"F2BA94AB-B85E-4EA2-9DF0-CDBED59930EA",{"Operator":106,"Negate":54,"CPEMatch":111},[112],{"Vulnerable":54,"Criteria":53,"MatchCriteriaID":113,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"8D9781C9-799A-4BDA-A027-987627A01633",[],[116],{"id":117,"eventType":118,"eventTime":119,"details":120,"label":121,"color":122},"44bde9a6-82af-4846-85f8-8dddd375b52a","NEW_NVD","2025-05-07T02:15:33.645314+00:00","New CVE added to NVD","Published to NVD","blue",{"lastModified":10,"cacheTime":124,"version":125},1795793400457,"2.0",{"score":127,"band":128,"action":129,"scoredAt":130},61,"Medium","Plan remediation","2026-11-27T07:12:04.859297+00:00"]